    Type 8202 - pH or redox potential transmitter, ELEMENT design

    Product Image Type 8202

    The depiction of the products may differ from the actual specific design.

    Please consider the technical attributes and Data Sheets.

    Type Description

    Type 8202 is a compact measurement device for pH values or redox potential (ORP): ● pH value: in liquids that are clean, dirty, or contain sulphide or protein. ● Redox potential value: in clean or dirty liquids, liquids with sulphide or protein, and liquids that have a low conductivity. Thus, due to the measurement device’s design, Bürkert has simplified installation and maintenance work. The Type 8202 device is available in two versions. ● The first one called ELEMENT standard is proposed either with three adjustable outputs (two digital outputs and one analogue output) or with four adjustable outputs (two digital and two analogue) and can be equipped with a display. The display is only required for start-up, configuration (e.g. selection of pH/ORP measurement, measuring range, units, calibration, limit values...) or as a process value display. ● The second called ELEMENT neutrino is a 2-wire device without display and with 4…20 mA current output. The Type 8202 converts the measuring signal, then displays various values in different measuring units for the ELEMENT standard version (if display is mounted) and computes the output signals, which are provided for the ELEMENT standard version via one or two M12 plug-in connections; for the ELEMENT neutrino version that is done with one M12 plug-in connection or on a terminal strip with a cable gland.

    • Integrated compact measurement device for direct connection to control level (PLC)
    • Parameterisation, calibration and transfer of parameterisation data all possible thanks to a removable display/configuration module
    • Fast and easy adaptation of the device between pH and ORP measurement
    • Use of 120 mm standard PG 13.5 pH/ORP probes with S8 connection. (Type 8203 recommended)
    • Simple one- or two-point calibration can be carried out directly on the unit; simulation of process values and diagnostic functions

    For selecting the correct product please refer to the technical data, images and notes for proper use according to the data sheet.

    Downloads

    Data Sheets

    Description
    Filesize
    Language / Country
    DTS Type 8202 data sheet | pH/ORP meter [ELEMENT version] 2 MB EN / EU
    DTS Type 8203 data sheet | pH and ORP probes 1 MB EN / EU
    DTS Type S022 data sheet | fitting for ELEMENT pH/resistive conductivity measurement devices 2 MB EN / EU
    DTS Typ 8202 Datenblatt | pH-/Redoxpotenzial-Messgerät [ELEMENT-Ausführung] 2 MB DE / DE
    DTS Typ 8203 Datenblatt | pH- und ORP-Sonden 1 MB DE / DE
    DTS Typ S022 Datenblatt | ELEMENT-Fitting für pH- und konduktive Leitfähigkeitsmessgeräte 2 MB DE / DE
    DTS Type 8202 fiche technique | pH- ou redox-mètre [conception ELEMENT] 2 MB FR / FR
    DTS Type 8203 fiche technique | Sonde de pH ou de potentiel d'oxydo-réduction (Redox) 1 MB FR / FR

    User Manuals

    Description
    Filesize
    Language / Country
    MAN Accessory Type 8026 8036 SE36 8202 8222 8228 ELEMENT | Display module 808 kB EN,FR,DE / EU
    MAN Operating Instr. Type S022 | Fitting for 8202+8222 ELEMENT,8202+8222 ELEMENT neutrino 2 MB EN / EU
    MAN Operating Instructions Type 8202 ELEMENT neutrino | pH- or redox transmitter 2 MB EN / EU
    MAN Operating Instructions Type 8202 ELEMENT | pH- or redox-meter 2 MB EN / EU
    MAN Operating Instructions type 8203 | pH probes and Redox probes 178 kB EN / EU
    MAN Service manual Type 8202 8222 ELEMENT neutrino | Gasket forthe connecting box 145 kB EN,FR,DE / EU
    MAN Service manual Type 8202 ELEMENT 8202 ELEMENT neutrino | Gasket for the sensor holder 135 kB EN,FR,DE / EU
    MAN Bedienungsanleitung Typ 8202 ELEMENT neutrino | pH- oder Redox-Transmitter 2 MB DE / EU
    MAN Bedienungsanleitung Typ 8202 ELEMENT | pH- oder Redox-Messgerät 2 MB DE / EU
    MAN Bedienungsanleitung Typ 8203 | pH- oder Redoxpotential-Sonden 182 kB DE / EU
    MAN Bedienungsanleitung Typ S022 | Fitting für 8202+8222 ELEMENT, 8202+8222 ELEMENT neutrino 2 MB DE / EU
    MAN Manual de instrucciones Modelo 8222 ELEMENT | Módulo de pantalla 548 kB ES / ES
    MAN Manuel d'util. Type S022 | raccord pour 8202+8222 ELEMENT,8202+8222 ELEMENT neutrino 2 MB FR / EU
    MAN Manuel d'utilisation Type 8202 ELEMENT | pH-mètre ou redox-mètre 2 MB FR / EU
    MAN Manuel d'utilisation type 8202 ELEMENT neutrino | Transmetteur de pH ou de potentiel redox 3 MB FR / EU
    MAN Manuel d'utilisation type 8203 | Sondes de pH et sondes de potentiel d'oxydoréduction 181 kB FR / EU
    MAN Návod k obsluze Typ 8202 | ELEMENT neutrino | Měřič hodnotypH nebo redoxního potenciálu 3 MB CS / CZ
    MAN Návod k obsluze Typ 8203 | Sonda pH nebo redoxního potenciál 217 kB CS / CZ

    Declaration of Conformity

    Description
    Filesize
    Language / Country
    ABD EU-DoC|EU Declaration 472 kB ML

    EU Material Compliance

    Description
    Filesize
    Language / Country
    ABD EU-DoC|EU Material Compliance 42 kB EN
    ABD EU-DoC|EU Material Compliance 43 kB FR
    ABD EU-DoC|EU Material Compliance 43 kB DE

    Flyers and Catalogues

    Description
    Filesize
    Language / Country
    MISC Analytical Meters 5 MB EN / EU
    MISC On/Off and Control Valves 1 MB EN / EU

    Videos

    Description
    Filesize
    Language / Country
    video Calibracion Sensor de pH y ORP mod.8202 10 MB ES / ES
    video Conexiones electricas 13 MB ES / ES
    video Configuracion Salidas Analogicas y Digitales 10 MB ES / ES
    video Display Sensor Element 13 MB ES / ES
    video Sensor de pH 8202 18 MB ES / ES

    My Comparison List